; Rev 1.0 - initial release ; Rev 1.1 - correspond to board release - no other changes AdapterId 06792h AdapterName "NeoTecH 2 Serial / 1 Parallel Adapter, SPM121 / SPM321" NumBytes 2 NamedItem Prompt "Serial Port A - I/O Address" Choice "Serial 2 (02F8h)" pos[0]=xx001xxxb io 02F8h-02FFh Choice "Serial 3 (3220h)" pos[0]=xx010xxxb io 3220h-3227h Choice "Serial 4 (3228h)" pos[0]=xx011xxxb io 3228h-322Fh Choice "Serial 5 (4220h)" pos[0]=xx100xxxb io 4220h-4227h Choice "Serial 6 (4228h)" pos[0]=xx101xxxb io 4228h-422Fh Choice "Serial 7 (5220h)" pos[0]=xx110xxxb io 5220h-5227h Choice "Serial 8 (5228h)" pos[0]=xx111xxxb io 5228h-522Fh Choice "Serial 1 (03F8h)" pos[0]=xx000xxxb io 03F8h-03FFh Help "This port can be assigned to Serial 1-8. Use the F5=Previous and F6=Next keys to change serial port assignments if you are in the 'Change configuration' window. Conflicting assignments are marked with an asterisk and must be changed to use the adapter." NamedItem Prompt "Serial Port A - Interrupt" Choice "Level 3" pos[1]=xxx001xxb int 3 Choice "Level 4" pos[1]=xxx010xxb int 4 Choice "Level 5" pos[1]=xxx011xxb int 5 Choice "Level 7" pos[1]=xxx100xxb int 7 Choice "Level 9" pos[1]=xxx101xxb int 9 Choice "Level 11" pos[1]=xxx110xxb int 11 Choice "Level 12" pos[1]=xxx111xxb int 12 Help "This port may be set to interrupt level 3,4,5,7,9,11 or 12. Use the F5=Previous and F6=Next keys to change serial port assignments if you are in the 'Change configuration' window." NamedItem Prompt "Serial Port B - I/O Address" Choice "Serial 3 (3220h)" pos[0]=10xxxxxxb pos[1]=xxxxxxx0b io 3220h-3227h Choice "Serial 4 (3228h)" pos[0]=11xxxxxxb pos[1]=xxxxxxx0b io 3228h-322Fh Choice "Serial 5 (4220h)" pos[0]=00xxxxxxb pos[1]=xxxxxxx1b io 4220h-4227h Choice "Serial 6 (4228h)" pos[0]=01xxxxxxb pos[1]=xxxxxxx1b io 4228h-422Fh Choice "Serial 7 (5220h)" pos[0]=10xxxxxxb pos[1]=xxxxxxx1b io 5220h-5227h Choice "Serial 8 (5228h)" pos[0]=11xxxxxxb pos[1]=xxxxxxx1b io 5228h-522Fh Choice "Serial 1 (03F8h)" pos[0]=00xxxxxxb pos[1]=xxxxxxx0b io 03F8h-03FFh Choice "Serial 2 (02F8h)" pos[0]=01xxxxxxb pos[1]=xxxxxxx0b io 02F8h-02FFh Help "This port can be assigned to Serial 1-8. Use the F5=Previous and F6=Next keys to change serial port assignments if you are in the 'Change configuration' window. Conflicting assignments are marked with an asterisk and must be changed to use the adapter." NamedItem Prompt "Serial Port B - Interrupt" Choice "Level 3" pos[1]=001xxxxxb int 3 Choice "Level 4" pos[1]=010xxxxxb int 4 Choice "Level 5" pos[1]=011xxxxxb int 5 Choice "Level 7" pos[1]=100xxxxxb int 7 Choice "Level 9" pos[1]=101xxxxxb int 9 Choice "Level 11" pos[1]=110xxxxxb int 11 Choice "Level 12" pos[1]=111xxxxxb int 12 Help "This port may be set to interrupt level 3,4,5,7,9,11 or 12. Use the F5=Previous and F6=Next keys to change serial port assignments if you are in the 'Change configuration' window." NamedItem Prompt "Parallel Port - I/O Address" Choice "Parallel 1 (03BCh)" pos[0]=xxxxx11xb io 03B0h-03BFh Choice "Parallel 2 (0378h)" pos[0]=xxxxx10xb io 0378h-037Fh Choice "Parallel 3 (0278h)" pos[0]=xxxxx01xb io 0278h-027Fh Choice "DISABLED " pos[0]=xxxxx00xb Help "This port can be assigned to Parallel 1-3 or disabled. Use the F5=Previous and F6=Next keys to change serial port assignments if you are in the 'Change configuration' window. Conflicting assignments are marked with an asterisk and must be changed to use the adapter." NamedItem Prompt "Parallel Port - Interrupt" Choice "Level 5" pos[1]=xxxxxx0xb int 5 Choice "Level 7" pos[1]=xxxxxx1xb int 7 Help "This port may be set to interrupt level 3,4,5,7,9,11 or 12. Use the F5=Previous and F6=Next keys to change serial port assignments if you are in the 'Change configuration' window."